FSCUT2000C laser cutting control system User Manual
20
Basic setting parameters of Delta A series
Parameter type Recommender value
P1-00
1102H
Implication
Control mode, position control mode
Negative logic pulse + direction.
Set the parameters as: 1102H, the maximum
pulse frequency is 4Mpps;
Set the parameters as: 0102H, the maximum
pulse frequency is 500K.
P1-01
P2-10
P2-14
P2-22
00
Select a position mode of external command
control
101
DI1 is set a SON servo enabling, NO logic
102
DI5 is set as ARST clear alarm function,
NO logic
007
DO5 is set as ALRM Servo alarm function
NC logic
The servo wiring diagram of Sanyo R series
Fscut-DB15
Sanyo-R-50Pin
signal pin
PUL+ 1
PUL- 9
DIR+ 2
DIR- 10
Shielding layer
pin signal
28 R-PC
29 R-PC
26 F-PC
27 F-PC
A+ 3
A- 11
B+ 4
B- 12
Z+ 5
Z- 13
3 AO+
4 AO-
5 BO+
6 BO-
7 Z0+
8 ZO-
24V 8
SON 6
CLR 7
ALM 14
0V 15
49 OUT-PWR
50 CONTCOM
37 CONT1
15 CONT8
46 OUT8
24 OUT-COM
Basic setting parameters of Sanyo R series
Parameter Recommended
Type
value
Implication
SY08
00
Set as position mode
Gr8.11
02
Select pulse signal input type: Pulse +
direction;
Gr9.00
00
Can be driven in co-rotation side
Gr9.01
00
Can be driven in reverse side