FSCUT2000C laser cutting control system User Manual
42
3.6.2 IPG laser configuration
PWM enable signal: Select a relay output port as PWM enable switch, which
can avoid laser leakage or wrong trigger under modulation mode.
DA Select: 1604V2 card provides 2 interfaces of analog quantity. Any interface
can control laser peak power. Don’t use this port when using serial port or n e t w o r
k remote control.
IPG fiber laser configuration: Remote start button:
After starting IPG remote control, CypCut software will monitor the state of
lasers in real time and can operate lasers by means of communication. Motions, such
as Emission, Guide beam, Current, etc, are realized. After selecting this option, DA
port will be not available.
IPG remote control provides serial port and network, so users can set serial port
or network IP address based on actual condition. If communication of PC, laser and
BCS 100 applies network communication, please pay attention to don’t repeat
segment. For example, if height controller segment is 10.1.1.x, and then laser can be
set as 192.168.1.x. From the perspective of system stability, network is recommended.
If using serial port communication, please pay attention to shell and shielding layer of
serial port connector must be ground connection.
    "