51 FSCUT2000C laser cutting control system User Manual
Chapter4 Electrical System Debugging
4.1 Power test
Connect BCL3766 External IO Board and BMC1604V2 control card with
C62and C37 cables, and provide 24V power for BCL3766 External IO Board. Before
turn on system power, please confirm whether power connection is correct or not and
whether positive and negative polarity of power is short circuit or not.
Notes: Prohibit plugging BMC1604V2 card, C62 and C37 cable with electric
heating!
4.2 All the hardware signal test
Start computer and CypCut software. Click “file” in menu above→“Diagnosis”.
Please check in sequence positive/negative/origin switch of each axis, input
signal, output signal, DA signal, PWM signal and servo-enabled signal.
For machines of double shaft drive, count value of encoders of two axes can be
reset through resetbutton. Then send 1000 test campaign about the status of each
axis, and ensure feedback pulse value and sent pulse value of encoder is in accord.
Setting method can refer to Appendix 7.1 "Scan cut" introduction file for more details.
4.3 Basic motion test
First, recommend setting servo driver parameters as conservative values. Also set
the parameters of CypCut as conservative values. Click “Layer” “Global
parameter” on CypCut. Parameter setting is shown as below:
    "