57 FSCUT2000C laser cutting control system User Manual
frequency, must be matched, with never transferring one value quite large and another
value quit small among these two parameters.
Level
1 2 3 4 5 6 7 8
Move
0.1 0.2 0.3 0.4 0.5 0.6 0.8 1
acc(G)
Move
2 3 4 5 5.5 6 6 6
Freq(HZ)
9 10
1.5 2
7 8
5.3.5 Set circle precision and corner precision
Generally, it’s not recommended that users modify the precision of arc and
corner. Under some special circumstances, you can fine tune these two parameters
within the range of default parameters.
If you are not satisfied with the accuracy of the arc, you can turn down the arc
precision parameters, at the same time the speed of process arc will be limited. The
smaller the value is, the more obvious the speed limit is. If you are not satisfied with
the accuracy of the corner, you can turn down the corner precision parameters, at the
same time the speed of turning the corner will decline. The smaller the value is, the
more obviously the speed declines. The higher the value is, the closer the corner will
be to a fillet.