CHAPTER 2 WIRING
The conditions for enabling position control with the command pulse input are shown below.
Servo-on [S-ON] = ON
Forced stop [EMG] = ON
(Control output ready for servo-on [RDY] = ON)
2
Position control (37) = ON
The command pulse is enabled while command pulse ratio 1
(27) or command pulse ratio 2 (28) remains turned on.
Function block diagram
Command pulse ratio 1(27)
Command pulse ratio 2(28)
Command pulse ratio 1
(PA2_54)
Command pulse ratio 2
(PA2_55)
Electronic gear numerator selection 0(24)
Electronic gear numerator selection 1(25)
Numerator 0 of electronic gear/ Denominator of electronic gear
(PA1_06)
(PA1_07)
Numerator 1 of electronic gear/ Denominator of electronic gear
(PA2_51)
(PA1_07)
Numerator 2 of electronic gear/ Denominator of electronic gear
(PA2_52)
(PA1_07)
Numerator 3 of electronic gear/ Denominator of electronic gear
(PA2_53)
(PA1_07)
2-46 Description of I/O Signals