CHAPTER 1 INSTALLATION
1.2 Servo Amplifier
1
1.2.1 Storage Environment
Select the following environment when storing the servo amplifier, or when resting the machine under
the state without power distribution.
Item
Environmental condition
Ambient temperature -20 to +80°C (no freezing allowed)
Ambient humidity 10 to 90% RH (no condensation allowed)
Location
Indoors at altitude 1000 m free from powder dust, corrosive gases
and direct sunlight
Atmospheric pressure 70 to 106 kPa
Vibration
3 mm(Max. amplitude): Less than 2 to 9 Hz,
9.8 m/sec2: Less than 9 to 20 Hz,
2 m/sec2: Less than 20 to 55 Hz, 1 m/s2: Less than 55 to 200 Hz
1.2.2 Operating Environment
Operate the servo amplifier in the following environment. The servo amplifier is neither dust proof nor
water proof.
Item
Environmental condition
Ambient temperature -10 to +55°C (no freezing allowed)
Ambient humidity 10 to 90% RH (no condensation allowed)
Location
Vibration
Indoors at altitude 1000 m free from powder dust, corrosive gases
and direct sunlight
3 mm(Max. amplitude): Less than 2 to 9 Hz,
9.8 m/sec2: Less than 9 to 20 Hz, 2 m/sec2: Less than 20 to 55 Hz,
1 m/sec2: Less than 55 to 200 Hz
Observe the following when operating.
Install indoors at a place free from rainwater and direct sunshine.
Do not operate in corrosive atmosphere including hydrogen sulfides, sulfurous acid, chlorine,
ammonia, sulfur, chlorine-based gases, acids, alkalis or salts or near flammable gases or matters.
Install in a well ventilated environment with less vapor, oil and water content.
Install at a place with less vibration or impact.
Do not operate in vacuum.
1-8 Servo Amplifier
    "