CHAPTER 2 WIRING
2.2 P-N Junction
Directly connect the DC link circuit of two servo amplifiers to exchange power.
In a system having a powering (driving) shaft and regenerating (back tension) shaft such as the
2
winder/unwinder unit, the power consumption of the entire system can be reduced. Do not supply main
power to the servo amplifier on the other side of the P-N junction.
The capacity of the servo amplifier on the PN junction side must be equal to or less than that of the
servo amplifier on the power supply side.
The capacity of the servo amplifier
The capacity of the servo amplifier
on the power supply side
≧ on the PN junction side
■Wiring example for frame 1
■Wiring example for frame 2 or over
P(+) N( - ) RB1 RB2
TB2
TB1
L1
L2
L3
P (+) N( - ) RB1 RB2
TB2
TB1
L1
L2
L3
P(+) N( - ) RB1 RB2 RB3
TB2
TB1
L1
L2
L3
P (+) N( - ) RB1 RB2 RB3
TB2
TB1
L1
L2
L3
For the details, contact the manufacturer.
2-16 P-N Junction