Error
code
Module
Type
Brief Description
Error Description
Recommended measures
13047 Error
Software type
打印失败,检测到PASS数据未打
印完成
Printing failed, PASS data has not
been printed
可能1.光栅异常
可能2.齿轮比异常
可能3.X限位或马达异常
可能4.喷车板连接异常
可能5.喷车板电源异常
可能6.主板程序或喷头板逻辑不匹配
Possible 1. Raster abnormality
Possible 2. Gear ratio abnormality
Possible 3. X limit or motor abnormality
Possible 4. Spray board connection abnormality
Possible 5. Spray board power supply abnormality
Possible 6. Mainboard program or printhead board
logic does not match
1.检测光栅是否正常
2.检测齿轮比是否正确
3.检测X限位是否正常
4.检测喷车板接线是否正常
5.检测喷车板供电是否正常
6.检测喷车板逻辑版本是否正确
1. Check if the grating is normal
2. Check if the gear ratio is correct
3. Check if the X limit is normal
4. Check if the wiring of the trolley board is normal
5. Check if the power supply of the trolley board is normal
6. Check if the logic version of the trolley board is correct
13048 Error
13049 Error
13050 Error
系统异常,测高器检测异常
Software type System abnormality, height meter
detection abnormality
可能1.测高器检测异常
可能2.固件配置不正确或被破坏
Possible 1. The altimeter detection is abnormal
Possible 2. The firmware configuration is incorrect
or damaged
1.检查测高器是否异常
2.重新导入正确的固件配置
1. Check if the altimeter is abnormal
2. Re-import the correct firmware configuration
等待马达停止超时
可能1.固件配置的参数时间太短
Software type Waiting for the motor to stop timed Possible 1. The parameter time of the firmware
out
configuration is too short
Software type
光栅抖动超时(1S)退出
Grating jitter timeout (1S) exit
可能1.马达或驱动器存在异常
Possible 1. There is something wrong with the
motor or driver
1.导入正确的固件配置和参数
1. Import the correct firmware configuration and parameters
1.检查马达或驱动器是否存在异常