Error
code
Module
Type
Brief Description
12519 Error
一级墨盒V墨瓶异常
Hardware type Abnormality of the primary V ink
bottle
Error Description
可能1.一级墨盒V墨瓶缺墨
可能2.浮球液位传感器损坏
Possible 1. The ink bottle of the primary ink
cartridge V is out of ink
Possible 2. The float level sensor is damaged
Recommended measures
1.请及时给V盒墨瓶供墨
2.请检查浮球液位传感器是否正常
1. Please supply ink to ink bottle V in time
2. Please check whether the float level sensor is normal
12520 Error
保湿下限位异常
Hardware type Abnormal lower limit of
moisturizing
可能1.主板和限位连接线异常
可能2.限位传感器异常
可能3.限位输入信号与板卡信号绑定错误
Possible 1. The mainboard and limit connection
line are abnormal;
Possible 2. The limit sensor is abnormal;
Possible 3. The limit input signal is incorrectly
bound to the board signal
1.主板和限位的线是否连接正常
2.限位传感器是否正常
3.导入正确的固件配置和参数文件
1. Check if the mainboard and limit wires are connected properly
2. Check if the limit sensor is normal
3. Check if the correct firmware configuration and parameter files are imported
12521 Error
保湿上限位异常
Hardware type Abnormal upper limit of
moisturizing
12522 Error
Hardware type
清洗原点限位异常
Abnormal cleaning origin limit
可能1.主板和限位连接线异常
可能2.限位传感器异常
可能3.限位输入信号与板卡信号绑定错误
Possible 1. The mainboard and limit connection
line are abnormal;
Possible 2. The limit sensor is abnormal;
Possible 3. The limit input signal is incorrectly
bound to the board signal
1.主板和限位的线是否连接正常
2.限位传感器是否正常
3.导入正确的固件配置和参数文件
1. Check if the mainboard and limit wires are connected properly
2. Check if the limit sensor is normal
3. Check if the correct firmware configuration and parameter files are imported
可能1.主板和限位连接线异常
可能2.限位传感器异常
可能3.限位输入信号与板卡信号绑定错误
Possible 1. The mainboard and limit connection
line are abnormal;
Possible 2. The limit sensor is abnormal;
Possible 3. The limit input signal is incorrectly
bound to the board signal
1.主板和限位的线是否连接正常
2.限位传感器是否正常
3.导入正确的固件配置和参数文件
1. Check if the mainboard and limit wires are connected properly
2. Check if the limit sensor is normal
3. Check if the correct firmware configuration and parameter files are imported
    "