Error
code
Module
Type
Brief Description
Error Description
Recommended measures
13038 Error
Software type
可能1.固件配置和固件参数不正确或被破坏
可能2.主板和喷车板连接不正常
可能3.限位开关失效或者接线异常
可能4.马达或者伺服运动异常
可能5.运动速度过慢导致超时
1.请导入正确的固件配置和参数。
可能6.主板程序与喷车板逻辑不匹配
2.请检查错误描述里的接线。
打印失败,执行PASS打印动作失
败
Printing failed, execution of PASS
printing action failed
Possible 1. The firmware configuration and
firmware parameters are incorrect or damaged
Possible 2. The connection between the mainboard
and the trolley board is abnormal
Possible 3. The limit switch fails or the wiring is
3.请检查马达或者伺服是否运动异常
4.请从软件版本Information里检查主板程序与喷车板逻辑版本是否匹配
1. Please import the correct firmware configuration and parameters.
2. Please check the wiring in the error description.
3. Please check whether the motor or servo is moving abnormally
abnormal
4. Please check whether the mainboard program and the trolley board logic version
Possible 4. The motor or servo movement is
match from the software version information
abnormal
Possible 5. The movement speed is too slow and
causes a timeout
Possible 6. The mainboard program does not match
the trolley board logic
13039 Error
Software type
可能1.固件配置和固件参数不正确或被破坏
可能2.主板和喷车板连接不正常
可能3.限位开关失效或者接线异常
可能4.马达或者伺服运动异常
可能5.运动速度过慢导致超时
1.请导入正确的固件配置和参数。
可能6.主板程序与喷车板逻辑不匹配
2.请检查错误描述里的接线。
打印失败,执行PASS打印后动作
失败
Printing failed, execution of Post-
PASS printing action failed
Possible 1. The firmware configuration and
firmware parameters are incorrect or damaged
Possible 2. The connection between the mainboard
and the trolley board is abnormal
Possible 3. The limit switch fails or the wiring is
3.请检查马达或者伺服是否运动异常
4.请从软件版本Information里检查主板程序与喷车板逻辑版本是否匹配
1. Please import the correct firmware configuration and parameters.
2. Please check the wiring in the error description.
3. Please check whether the motor or servo is moving abnormally
abnormal
4. Please check whether the mainboard program and the trolley board logic version
Possible 4. The motor or servo movement is
match from the software version information
abnormal
Possible 5. The movement speed is too slow and
causes a timeout
Possible 6. The mainboard program does not match
the trolley board logic