1. G Function Description
tapping pitch / feed rate reduce:
G94: F (mm/min) =S (RPM) * P (mm/rev)
G95: F (mm/rev) = P (mm/rev)
G74: when performing, feedrate(F), spindle RPM(S), they are not
controlled by turning switch(fixed at 100%)
88
    "