EzCad2UNI Users Manual
Minute: Use current computer clock's minute for the corresponding text.
Second: Use current computer clock's second for the corresponding text.
Time Section: Divides into 24 time sections one day of 24 hour, the user may define each
time section is a text. This function mainly uses in the work piece the processing needing to have
the number of runs information.
TCP/IP communication
When the operation is taking place, the system will pick up the text from the network.
Notice: The network interface in here is the network interface uses in TCP/IP agreement.
When the user selected the TCP/IP communication, the parameter defines will display
automatically in the dialog box, see the figure 4-41:
Figure 4-41 TCP/IP communication parameter definition
IP Address: select the IP address which from reads the data
Port: select the port the TCP/IP communication used
Command: When the system processes to this text object, the system through the
network interface to transmit this order character string to a computer assigned the IP address,
request the computer sends the character string needs to process at present, the system will not
return until the computer replied, after the response of the computer, the system will process the
returns text automatically.
Unicode: After choosing this option, the system to the computer transmission which and
the read character is the Unicode form, otherwise is the ASCII form.
The following example showed how to use this function:
Now has a customer to process 10000 work pieces, on the work piece the marking content is
a text, but each work piece must process the text content is dissimilar, therefore, before each work
piece processing, must real-time read the processing content through the network from the local
area network a computer server (IP: 192.168.0.1 port is 1000) on.
1Open ezcad2 to establish a text object, adjust the text size, the position and the
processing parameter.
2Choice the text object, select the enables variable text, click the increasebutton, the
system will spring a Figure dialog box as 4-32, select TCP/IP communication, set the
network interface parameter, the IP address parameter fills in server computer's IP, here
is 192.168.0.1; the port parameter sets to use in the communication the port number, here
is 1000, the network interface parameter must identically with the server computer on ,
otherwise it will cause to be unable communication.
3Set the command is TCP: Give me string.(This command may for the random server
definition command)