XC3000S Series Laser Cutting
System Commissioning Manual
DC power 24V to the cathode of the diode, DC power 0V to the anode of the diode; Connection in
reverse will lead to a short circuit.
6.1.2 Power supply wiring specification
1、The power supply requires electrical installation specifications and separation of low and high
voltage.
2、 24 power supply and payload with the relatively large interference (such as servo, solenoid
valve) and the controller should take power supply separately.
3、 Servo grounding recommended to use star connection, as the correct connection can ensure
the stable operation of the equipment.
6.2 F-axis abnormality handling method
If F-axis control is abnormal without alarm when using axis control mode to control F-axis, please
follow the steps below to troubleshoot.
131