XC3000S Series Laser Cutting
System Commissioning Manual
5.1.3 Current configuration area
You can view the current profile's point link definition and connection order in this area.
You can also add, insert, change or delete slave and point link information; Please refer to section 5.3 for
details.
5.1.4 Online Module Area
This area will only appear when the configuration of the current configuration area is different from the
actual configuration, at which time the module online detection button will also have a red flashing alert.
5.1.5 PLC Variable Area
The PLC Variables area lists all PLC variables, and point link information.
5.1.6 PLC Variable Pin Selection
You can select variables by variable type, and find the required PLC variables faster.
5.1.7 Journal area
The log area displays important information such as the status of the connection to the master, whether the
activation was successful, etc.
5.1.8 Status Area
The status area shows whether the CNC master is offline, whether the configuration platform is pipe
cut or flat, the version number of the XStudio compilation, the Information such as whether the CCD pin
is supported.
10
    "