Yaskawa Servo Parameter Setting
Recommended
Parameter Type
Value
Setting range
Pn000
Pn000
Pn200
Pn50A
0.0.1.0
0.1.0.1
0.0.0.0
8100
0.0.x.0 (0 speed; 1 position) 0.0.0.X (0 forward; 1 reverse)
0.X.0.0 (0 3-phase power; 1 single-phase power); 0.0.0.X (0
display setting, 1 display all parameters)
0.0.0.X (0pulses +direction positive logic, 5 pulses +direction
negative logic) .
X.0.0.0 (linear 1M)
Positive turn prohibition cancellation
Pn50B
6548
Reverse prohibition cancellation
31
    "