XC3000S Series Laser Cutting
System Commissioning Manual
All DO1~DO16 output 24V high level, with the maximum output current of 0.5A. If it’s connected to a
high- power load, please connect an external relay and connect a current- continuing diode (MIC 10A6) in
parallel with the oxygen and nitrogen solenoid valve.
In addition, it is better to use another power supply DC24V2 control valve, which can be separated from
the system IO power supply DC24V1.
Take the shown below as an example:
solenoid valve
2.3.5 Analog input interface
A total of 4 A/I analog input interfaces are provided, with a signal input range 0V ~ 10V.
2.3.6 Analog input interface
A total of 4 A/O analog output interfaces are provided, with a signal output range 0V ~ 10V. The way is as
shown in the figure.
20