Max follow-up offset 5mm
System Latency
5
XC3000S Series Laser Cutting
System Commissioning Manual
When the absolute value of the difference between the
commanded position and the actual position is greater than
this value, the software will alarm and shut down.
Axis motion delay time
Manual slow
0. 12m/min Running slowly in manual mode
Manual fast
0.24m/min Run fast in manual mode
Speed
1.8m/min Running speed in automatic mode
Acceleration
2000mm/s Running acceleration in automatic mode
Acc time
500
Time to run acceleration completion in automatic mode
Motor polarity
1
Max torque
200
Under torque control, changing the motor polarity can
change the direction of motion
Max torque value
Torque feedforward 0
Adjmt. coefficient
Homing mode
Absolute
Default
Incremental: Find the zero signal back to zero and use the
zero signal as the reference point
Absolute: Move to the zero position of the driver feedback with the
position 0 of the driver feedback as the reference point
92
    "