XC3000S Series Laser Cutting
System Commissioning Manual
7.6.12 Physical button
Parameter Name
Start signal l ogic
Pause signal logic
Reset signal logic
Emergency stop alarm logic
Red light
Yellow light
Green light
Physical button
Default Value Remarks
DI14
NO
Settable start signal input pins
NO: No signal output in untriggered, select this item.
NCsignal output in untriggered, select this item.
DI17
NO
Not use
NO
DI13
NO
DO13
DO14
DO15
Settable pause signal input pins
NO: No signal output in untriggered, select this item.
NCsignal output in untriggered, select this item.
Settable reset signal input pins
NO: No signal output in untriggered, select this item.
NCsignal output in untriggered, select this item.
Settable emergency stopping alarm signal input pins
NO: No signal output in untriggered, select this item.
NCsignal output in untriggered, select this item.
Red light of tricolor lamp
Yellow light of tricolor lamp
Green light of tricolor lamp
92
    "