Safety door alarm stop
processing
Laser brand
XC3000S Series Laser Cutting
System Commissioning Manual
Unchecked When checked, processing will be stopped when the
safety gate alarm is activated during processing
IPG
Just choose by the actual laser brand
Laser power
1000
Average power of the filled laser
Frequency
5000
Fill in the laser frequency, commonly 5000Hz
Voltage of max power
10
Feedback voltage of max 10
power
Analog output delay
0
FlyCut laser on delay
0
FlyCut laser off delay
0
Fill in the maximum value of the laser feedback power
analog, commonly 5V and 10V
Fill in the maximum value of the laser feedback power
analog, common 5V and 10V
Output delay 0 are filled in advance.
The analog output is filled in advance and then output
enable signal and PWM signal, generally for 50ms
How many ms in advance of the flying cut? This
parameter is usually filled in 0, and it is recommended
to use the advance distance in the nesting to adjust
whether the flying cut contour is closed or not.
How many ms of flying cut lag to turn off the light? This
parameter is usually filled in 0, and it is recommended to
use the advance distance in the nesting to adjust
whether the flying cutting contour is closed or not.
7.6.8 Assist gas cell valve and analog output settings