Figure 3.2 - Positions of the joints of water pipe and gas pipe
Outer diameter of water pipe
caliber
Minimum flow speed
Entry pressure
Entry temperature
Hardness (relative to CaCO3)
PH range
Particles size available
6mm
1.8L/min0.48gpm
170-520kPa (30-60 psi)
≥room temperature /dew
point
250mg/liter
6 to 8
Diameter less than 200 microns
This water-cooled interface is designed as a closed-loop water-cooled system that can also be
used in conjunction with external free water supply and must meet the requirements in the above
list.
2.2.2 Assist Gas Interface
The impurity in auxiliary gas such as hydrocarbon and steam will damage the lens and cause
cutting power fluctuation as well as inconsistencies between the sections of the work piece. The
form below is the recommended auxiliary gas specification. The higher the purity of the gas, the
V1.0