The solution
1.Replace coolant and oil filter
2. Purge the radiator and the internal door panel filter with high-pressure air
3. In case the fan reaches 95 degrees or the monitor shows that the fan does not start on time, contact the
after-sales personnel in time
3、故障现象:机组油耗大或压缩空气含油量大
①冷却剂量太多,正确的位置应在机组加载时观察,此时油位应不高于一半;
②回油管堵塞;
③回油管的安装(与油分离芯底部的距离)不符合要求;
④机组运行时排气压力太低;油分离芯破裂;
⑤分离筒体内部隔板损坏;机组有漏油现象;
⑥冷却剂变质乳化或超期使用。
⑦使用的油分芯不符合设备压力密度不够
解决办法
①打开排油阀,检查排出来的油是否含水是否乳化,如含水量较大应及时更换。
②更换油分芯以及过滤芯
③疏通回油管
3, fault phenomenon: the unit fuel consumption or compressed air oil content is large
1.Too much cooling dose, the correct position should be observed during unit loading, at this time the oil level
should not be higher than half;
2. return tubing blockage;
3. the installation of the return pipe (distance from the bottom of the oil separation core) does not meet the
requirements;
4. the exhaust pressure of the unit is too low during operation; Oil separation core rupture;
5. The internal partition of the separation cylinder is damaged; The unit has oil leakage phenomenon;
6. The coolant is emulsified or used over time.
7.The oil core used does not conform to the equipment pressure density is not enough
The solution
1. Open the oil discharge valve, check whether the discharged oil contains water or is emulsified, such as large
water content should be replaced in time.
2. Replace the oil core and filter element
3. Dredge the return pipe
4、故障现象:机组压力低
①进气阀故障,导致无法正常进气
②空滤过脏,导致进气不通畅
③管道阀门问题,有漏气或者阀门未关闭导致气压异常
④有吸干机,或者其他有排期机组
-2-
    "