4. Indexing Position Operation
STOP
When the stop signal (Rising Edge) is input, the motor stops at the set deceleration (0x6085),
ending the index operation sequence.
When the start signal is input again, the operation resumes from the index set as the start
index (0x3008).
Speed
START
SVON
STOP
STOP 입력
Deceleration pattern when the stop
감속 패턴 signal is input
Original deceleration
pattern
Time
4-24
    "