4. Indexing Position Operation
Next Index
It sets the number of the next index to automatically perform after the existing index is
complete, If the action of the existing index is set to Next Index(set value 2).
Please see the explanation of ‘Next Index’ for further details.
Action
Under the Indexing Position mode, one of the three methods can be used depending on the
action of the index.
Stop
If the action of the index is set to Stop (set value 0), the overall sequence is completed after the
relevant index is complete.
When the start signal is input from outside, the indexing position operation begins from the index
(0~63) set as the start index (0x3008).
Speed
Time
4-13