15. Communication Protocol
(7) Write Multiple Coils (0x0F)
Excute ON or OFF to the value of continuative bit input
Request
Function code
Starting Address
Quantity of Registers
Byte Count
Outputs Value
1Byte
2Byte
2Bytes
1Bytes
N* x 1 Byte
Request OK
Function code
Starting Address
Quantity of Registers
Response not OK
Error code
Exception code
1Byte
2Byte
2Byte
1Byte
1Byte
0x0F
0x0000 to 0xFFFF
0x0000 or 0xFF00
N*
*N = Quantity of Outputs / 8
0x0F
0x0000 to 0xFFFF
0x0001 or 0x07B0
0x8F
0x01 ~ 0x04
Command code : Write Single Coil can control continuous bit input of drive status input 1, 2.
The corresponding address of drive status input and output 1,2 are as below.
Drive status input 1, 2 communication address
Communication
address
decimal Hexa
0
0x0000
1
0x0001
2
0x0002
3
0x0003
4
0x0004
5
0x0005
6
0x0006
Output
contacts
POT
NOT
HOME
STOP
PCON
GAIN2
P_CL
Accessi
bility
RW
RW
RW
RW
RW
RW
RW
Communication
address
decimal Hexa
16
0x0010
17
0x0011
18
0x0012
19
0x0013
20
0x0014
21
0x0015
22
0x0016
Output
contacts
Accessi
bility
START
RW
PAUSE
RW
REGT
RW
HSTART
RW
ISEL0
RW
ISEL1
RW
ISEL2
RW
15-15