13. Object Dictionary
1
Capture negative edge position value of touch probe 2
14 to 15
–
Reserved
0x60B9
Variable
Format
UINT
Setting Range
-
Touch Probe Status
Default
Value
-
Accessi PDOAllo
Unit
bility
cation
-
RO
Yes
Change
Property
-
ALL
Store
No
Shows touch probe status.
Bit
0
1
2
3 to 5
6
7
8
9
10
11 to 13
14
15
Value
0
1
0
1
0
1
–
0, 1
0, 1
0
1
0
1
0
1
–
0, 1
0, 1
Do not use touch probe 1
Use touch probe 1
Descriptions
Positive edge position value of touch probe 1 is not stored
Positive edge position value of touch probe 1 is stored
Negative edge position value of touch probe 1 is not stored
Negative edge position value of touch probe 1 is stored
Reserved
Toggled when positive edge position value of touch probe 1 is
updated
Toggled when negative edge position value of touch probe 1 is
updated
Do not use touch probe 2
Use touch probe 2
Positive edge position value of touch probe 2 is not stored
Positive edge position value of touch probe 2 is stored
Negative edge position value of touch probe 2 is not stored
Negative edge position value of touch probe 2 is stored
Reserved
Toggled when positive edge position value of touch probe 2 is
updated
Toggled when negative edge position value of touch probe 2 is
updated
In continuous trigger mode, bits 6,7,14,15(store all values for touch probe positive/negative edge)are
toggled.
To disable bits 1,2,9,10 of touch probe status(0x60B9)(store position values for positive/negative edge
of touch probe 1, 2), first disable bits 4,5,12,13 (use sampling values for positive/negative edge of
touch probe 1, 2) and then toggle Enable.
0x60BA
Variable
Format
DINT
Touch Probe 1 Positive Edge Position Value
Setting Range
-
Default
Value
-
Accessi PDOAllo
Unit
bility
cation
UU
RO
Yes
Change
Property
-
ALL
Store
No
Shows positive edge position value of touch probe 1.
13-93