2. Wiring and Connection
** SPD1
** SPD2
** SPD3
** MODE
Selecting command speed for Depending
on Speed Digital Input contact, Speed
command is changed as below
Input device
SPD1 SPD2 SPD3
Speed
Speed Command 1
X
X
X
(Parameter 0x2312)
Speed Command 2
O
X
X
(Parameter 0x2313)
Speed Command 3
X
O
X
(Parameter 0x2314)
Digital Speed 1
Speed Command 4
O
O
X
(Parameter 0x2315)
Speed Command 5
X
X
O
(Parameter 0x2316)
Speed Command 6
O
X
O
(Parameter 0x2317)
Speed Command 7
X
O
O
(Parameter 0x2318)
Speed Command 8
O
O
O
(Parameter 0x2319)
Digital Speed 2
When the AOVR signal is ON, the index
operation speed is overridden in
accordance with the voltage input into the
A-OVR(AI2)
The override value is 0% under -10Vinput,
100% under 0V input, and 200% under
+10V input.
Digital Speed 3 Selecting command speed for Depending
Conversion of on Speed Digital Input contact, Speed
control mode command is changed as below
2-12