2. Wiring and Connection
2.5.1 Names and Functions of Digital Input/Output
Signals
Names and Functions of Digital Input Signals(I/OConnector)
Pin No. Name Allotment Description
Function Details
21, 11 +24V
12
DI1
13
DI 2
14
DI3
15
DI4
16
DI 5
17
DI 6
18
DI 7
DC 24V
SVON
POT
NOT
A-RST
START
STOP
REGT
DC 24V INPUT COMMON
Servo ON
When the SVON signal is ON, the product
is operational (Servo ON)
When the signal is OFF, the motor goes
into the free run state.
No
forward(CCW)
rotation
The motor is stopped so that the actuator
cannot rotate forward more than the set
motion window [0x2013] The set value
determines how it stops.
No
backwrad(CW)
rotation
The motor is stopped so that the actuator
cannot rotate reverse more than the set
motion window [0x2013] The set value
determines how it stops.
Alarm reset Turns off the Servo alarm.
Initiate
operation
Intiatesoperation to the index position
operation.
Stop servo Stops operation.
Post-sensor
operation
If the index type is registration absolute
orregistration Relative, when the REGT
signal is on, the speed and distance is
changed to the preset speed and distance.
When the EMG signal is on, the servo
19
DI 8
EMG
Emergency makes an emergency stop, generating ‘W-
stop
80’. [0x2013] The set value determines
how it stops.
2-10
22
DI 9
HOME
Origin Sensor
Home sensor input signal, used when
returning to the origin.
23
DI 10
HSTART
Initiate Origin
Operation
Initiates operation back to the origin
24
DI 11
ISEL0
Select Index 0
25
DI 12
ISEL1
Select Index 1
26
DI 13
ISEL2
Select Index 2 Select an index for operation among index
27
DI 14
ISEL3
Select Index 3 0 to 63.
28
DI 15
ISEL4
Select Index 4
29
DI 16
ISEL5
Select Index 5
** PCON
P Control
Action
When the PCON signal is on, PI control
changes to P control.
** GAIN2
Gain 1,2
Transfer
When the GAIN2 signal is on, the speed
control changes from Gain 1 to Gain 2.
** PCL
Limit positive
torque
When the PCL signal is on, positive torque
is limited. [0x2110] You can preset the
action, and the torque limit is determined
by [0x2111].