12. Object Dictionary
0x260A
Variable
Format
DINT
Setting Range
-
MultiTurn Data
Default
Value
-
Accessi PDOAllo
Unit
bility
cation
rev.
RO
Yes
Change
Property
-
ALL
Store
No
Shows the multi-turndata of multi-turn enconder.
0x260B
Variable
Format
INT
Setting Range
-
Drive Temperature 1
Default
Value
-
Accessi PDOAllo
Unit
bility
cation
oC
RO
No
Change
Property
-
ALL
Store
No
The temperature is measured with the built in temperature sensor in the drive’s power board. When
the measured value is 95 or above, the drive overheating alarm 1(AL-22) is set off.
0x260C
Variable
Format
INT
Setting Range
-
2
Drive Temperature 2
Default
Value
-
Accessi PDOAllo
Unit
bility
cation
oC
RO
No
ALL
Change
Property
-
Store
No
The temperature is measured with the built in temperature sensor in the drive’s power board. When
the measured value is 90 or above, the drive overheating alarm 1(AL-25) is set off.
0x260D
Variable
Format
INT
Setting Range
-
Encoder Temperature
Default
Value
-
Accessi PDOAllo
Unit
bility
cation
oC
RO
No
Change
Property
-
ALL
Store
No
Shows the temperature measured by the built in sensor of serial encoders (when encoder format
(0x0201) is 4). When the measured 90 or above, the encoder heat (AL-26)sets off.
0x260E
Variable
Format
UINT
Setting Range
-
Motor Rated Speed
Default
Value
-
Accessi PDOAllo
Unit
bility
cation
rpm
RO
No
Change
Property
-
ALL
Store
No
Shows the rated speed of the drive motor.
13-68