13. Object Dictionary
0x2504
Variable
Format
UINT
Setting Range
50 to 5000
Notch Filter 2 Frequency
Default
Value
5000
Accessi PDOAllo
Unit
bility
cation
Hz
RW
No
Change
Property
Servo Off
ALL
Store
Yes
0x2505
Variable
Format
UINT
Setting Range
1 to 100
Notch Filter 2 Width
Default
Value
1
Accessi PDOAllo
Unit
bility
cation
Hz
RW
No
Change
Property
Servo Off
ALL
Store
Yes
0x2506
Variable
Format
UINT
Setting Range
1 to 5
Notch Filter 2 Depth
Default
Value
Accessi PDOAllo
Unit
bility
cation
1
-
RW
No
Change
Property
Servo Off
ALL
Store
Yes
0x2507
Variable
Format
UINT
Setting Range
50 to 5000
Notch Filter 3 Frequency
Default
Value
5000
Accessi PDOAllo
Unit
bility
cation
Hz
RW
No
Change
Property
Servo Off
ALL
Store
Yes
0x2508
Variable
Format
UINT
Setting Range
1 to 100
Notch Filter 3 Width
Default
Value
1
Accessi PDOAllo
Unit
bility
cation
Hz
RW
No
Change
Property
Servo Off
ALL
Store
Yes
0x2509
Variable
Format
UINT
Setting Range
1 to 5
Notch Filter 3 Depth
Default
Value
1
Accessi PDOAllo
Unit
bility
cation
-
RW
No
Change
Property
Servo Off
ALL
Store
Yes
13-61
    "