13. Object Dictionary
Resupply
Allocates the function of I/O connector’s digial output signal 2, and sets the output signal level. See
the descriptions on 0x2210 for more detailed explanation.
0x2212
Variable
Format
UINT
Setting Range
0 to 0xFFFF
Digital Output Signal 3 Selection
Default
Value
Accessi PDOAllo
Unit
bility
cation
0x8001x
-
RW
No
Change
Property
Power
Resupply
ALL
Store
Yes
Allocates the function of I/O connector’s digial output signal 3, and sets the output signal level. See
the descriptions on 0x2210 for more detailed explanation.
0x2213
Variable
Format
UINT
Setting Range
0 to 0xFFFF
Digital Output Signal 4 Selection
Default
Value
Accessi PDOAllo
Unit
bility
cation
0x0005
-
RW
No
Change
Property
Power
Resupply
ALL
Store
Yes
Allocates the function of I/O connector’s digial output signal 4, and sets the output signal level. See
the descriptions on 0x2210 for more detailed explanation.
0x2214
Digital Output Signal 5 Selection
ALL
Variable
Format
UINT
Setting Range
0 to 0xFFFF
Default
Value
0x0010
Accessi PDOAllo Change
Unit
Store
bility
cation
Property
-
RW
No
Power
Resupply
Yes
Allocates the function of I/O connector’s digial output signal 5, and sets the output signal level. See
the descriptions on 0x2210 for more detailed explanation.
0x2215
Variable
Format
UINT
Setting Range
0 to 0xFFFF
Digital Output Signal 6 Selection
Default
Value
Accessi PDOAllo
Unit
bility
cation
0x0011
-
RW
No
Change
Property
Power
Resupply
ALL
Store
Yes
Allocates the function of I/O connector’s digial output signal 6, and sets the output signal level. See
the descriptions on 0x2210 for more detailed explanation.
13-43