2. Wiring and Connection
2. Wiring and Connection
2.1 Servo Motor Installation
2.1.1 User Environment Requirement
Items
Surrounding
Temerature
Surrouding
Humidity
External
Vibration
Environment Requirements
0 ∼ 40[℃]
80[%]RH or below
Vibration Acceleration
X, Y direction / 19.6[㎨] or below
Notes
When the temperature exceeds the workable
temperature, a separate command must be placed after
consulting with the Tech Department
Please use the product where no steam is generated
Excessive vibration may shorten the life cycle of the
bearings
2.1.2 Preventing Excessive Impact
Excessive impact on the motor during installation or accidental fall may destroy the encoder.
Caution
2.1.3 Wiring with Motor
Directly connecting the motor with commercial power damages the motor. Please use the
designated drive to connect power.
Please connect the earthing terminal of the motor to one of the two earthing terminals of the drive,
and connect the other terminal with a Type-3 ground connection.
U – U
V - V
W – W
- F.G
Please match the U, V, W terminals of the motor with the U, V, W terminals of the drive.
Please check the motor connector for any missing pin or bad contact.
If the motor has humidity or condensation, please check if the insulation resistance is 10[㏁] or
more (500[V]), and install the product only when there is no problem.
2-1