10. Application Functions
Example) When the set value is 0x0006
0
0
0
6
CONTACT
A
GAIN2Allocation
Contact A: Base status is 0(Low). Activates when
input.(Active High)
0x11
0x12
0x13
0x14
0x15
0x16
0x17
0x18
0x19
0x1A
0x1B
0x1C
0x1D
0x1E
0X20
0X21
0X22
0X23
PAUSE
REGT
HSTART
ISEL0
ISEL1
ISEL2
ISEL3
ISEL4
ISEL5
ABSRQ
JSTART
JDIR
PCLR
AOVR
SPD1
SPD2
SPD3
MODE
Contact B: Base statusis 1(High). Activates when 0(Low) is input (Active Low)
1(High) is
Example of Input SignalAllocation
The table below shows an example of allocating input signals. Please note the set values of
0x2200~0x220F.
DI1
SV_ON
(CONTAC
T A)
DI 9
HOME
(CONTAC
T B)
DI2
POT
(CONTAC
T A)
DI 10
HSTART
(CONTAC
T B)
DI3
NOT
(CONTAC
T A)
DI 11
ISEL0
(CONTAC
T A)
DI4
A-RST
(CONTAC
T A)
DI 12
ISEL1
(CONTAC
T A)
DI 5
START
(CONTAC
T A)
DI 13
ISEL2
(CONTAC
T A)
DI 6
STOP
(CONTAC
T A)
DI 14
ISEL3
(CONTAC
T A)
DI 7
REGT
(CONTAC
T A)
DI 15
ISEL4
(CONTAC
T A)
DI 8
EMG
(CONTAC
T A)
DI 16
ISEL5
(CONTAC
T A)
10-9