machine
Home offset: If the shaft can make the hard limit protection,often should set the value of
2~5mm,if set to 0,then the axes coordinate zero run to minimum,effective,has the potential to limit
such trigger error limit protection function,emergency stop the machine,if can not make the hard
limit protection,can set value is 0~5mm.
Contrl mode:Double pulse and pulse+direction mode optional,depending on the of motor drive
machine actual configuration decision,general model for pulse+direction
Step length;Namely motor pulse equivalent, send a pulse to the motor, the corresponding motion axis through the
absolute distance value.Before this value is set up correctly, can let the machine cutting a large rectangular
(graphics is bigger, can make the error smaller), automatic calculation by graphic length and measuring the length
of the step motor.
Enable limit trigger:Whether used for enabling the axis of the hard limit protection function.
PWM rising edge valid:Used to set the motor drives the pulse signal is rising falling edge along the efficient
or effective, when not enabled the falling edge controller using effective;When this is enabled, use the rising along
the effective controller.
Enable Home:If machine configuration with the shaft, the shaft "reset enabled" option should be open, if not
configured the shaft, then the shaft "reset enabled" option should be banned.The meaning of this parameter is to
control the "reset" boot options in the user preferences and function keys in the "reset" the axis function, prevent
users mistakenly to reset the shaft moving that doesn't exist.
Jump-off speed:Movement speed of shaft directly start from stationary state, if the value is too big, can lead to
motor lose step, jitter, and even produce the noise and set is too small, can reduce the running speed of the
graphics.The heavier if the large inertia of moving axis (axis), can install a smaller takeoff speed, if the movement
axis of inertia smaller lighter (shaft), can be appropriately increase the rotate speed.Typical values such as 5 ~ 30
mm/s.
Max speed:The shaft can withstand maximum speed.The parameters and inertia motor drive power, motor shaft,
and gear ratio.Typical values such as 200 ~ 500 mm/s.
Max Acc:Motor shaft in the maximum acceleration and deceleration motion, acceleration set is too large, also
can lead to motor lose step, jitter, and even produce the noise and set is too small, can lead to speed up slow and
reduce the running speed of the graphics.Corresponding to the large inertia axis, such as beam of the Y axis, a
typical setting for the range of 800 ~ 3000 mm/s2, corresponding to the axis of inertia small, such as the car of the
X axis, a typical setting range is 8000 ~ 20000 mm/s2
EStop acc:Can make the hard limit protection, if the shaft, when the axial movement to the limit position, to the
shaft to stop operation for emergency stop acceleration deceleration.This value may take the maximum
acceleration of 2 ~ 3 times
Keying
Jump-off speed:Keys on the keyboard to move the axis movement starting speed, not above the shaft rotate
speed
Acc:Buttons move the axis motion acceleration value, cannot be higher than the maximum acceleration
Invert direction:
Used to control the movement of the manual button when the mobile movement axis direction.When set the right
direction of polarity parameters, if press the direction key on the operation panel, the axial direction, which buttons
can reverse.