4.10.5Laser Dot Parameters Setting
4.11 Vendor settings
4.11.1The motor parameters
X Y Z U axis parameters
Dir polarity:Change the direction of polarity can make the motor to the reverse direction.Modify
the goal is to make the shaft to the origin when reset,if reset when the axial direction away from
the origin,explain the polar axis direction set wrong,should be modified.
Limiter polarity:Used to set the limit of high and low level signal model,If moving axis reaches
the limit position ,enter a low level signal to the main board ,the limit should be set to a negative
polarity
Breadth:The longest distance between the axes can walk,according to the actual situation of the