DATA Frame:8 E 1
5/14/2018
Start
bit
bit0
bit1
bit2
b it3 bit4
bit5 bit6
bit7
Even
bit
Stop
bit
8-data bits
11-bits character frame
DATA Frame:8-O-1
Start
bit
bit0
bit1
bit2
b it3 bit4
bit5 bit6
bit7
Odd
bit
Stop
bit
8-data bits
11-bits character frame
1 0 - b i ts ( f o r A S C I I )
DATA Frame:7-N-2
Start
bi t
bit0 bit1
bit2
bit3 bit4
bit5
bit6
Stop
bit
Stop
bi t
7-data bits
10-bits character frame
DATA Frame:7-E-1
Start
bi t
bit0
bit1
bit2
bit3 bit4
bit5 bit6
Even
bi t
Stop
bi t
7-data bits
10-bits character frame
DATA Frame:7-O-1
Start
bi t
bit0
bit1
bit2
bit3 bit4
bit5 bit6
Od d
bi t
Stop
bi t
7-data bits
10-bits character frame
Code
Name
Fuling
Inve r te r
Use r
Ma nua l
F6.03
- slide
pdf
Communi
.cr eosmp o n s e
cation
delay
0~2 00 ms
Value
5ms
Response delay: means the interval t ime from the end of data receive to transmitting response dat a to
upper level machine. If response de lay time is smaller than system operation time, resp onse delay time
should be system operation time. If re sponse delay time is longer than system operation time, inverter can
not transmit data to upper level machine until response delay time reached.
Function
Code
F6.04
Name
Communication
overtime fault time
Setting Range
0 .0(i n va li d),0 .1~10 0. 0s
Default
Value
0.0s
When this parameter is set to be 0. 0s, this function is invalid.
When this function is valid, if the interval time between two communications exceeds communication
overtime time, it will cause communication fault (E018).
Function
Code
Name
F6.05
Communication
error measure
Setting Range
0:Alarm and free run stop
1:No alarm and keep running
2:No alarm and stop according to
stop mode(by communication)
3:No alarm and stop according to
stop mode(by all control mode)
Default
Value
1
Function
Code
Name
F6.06
Response
measure
Setting Range
0:Response when write
1:No response when write
Default
Value
0
When this parameter is set to be 0, Response when write.
When this parameter is set to be 1, N o Response when write.This function can improve communiation
speed.
-71-
-72-
http://slide pdf.c om/re a de r/full/fuling-inve r te r-use r-ma nua l