This parameter defines four different contr ol modes which controls the inverter operation through
5/14/201e8xternal terminals.
0: Two-wiretype control, integrate Enable with direction. This mode is the most oft en used two-wire
control mode. The motor forward and reverse operations a re determined by the defined FWD and REV
terminal command.
K1
FWD
DZB
K2
REV Series
DCM
K1
OFF
ON
OFF
ON
K2
OFF
OCopmermataionnd
STOP
OFF
FWD
ON
REV
ON
STOP
3: Three-wire control, separate Enable from direction. At this mode EN is the Enable terminal, SW1 or
Fuling Inverter User ManuaSlW- s2liddeefpindef.ocpoem rating command and control direction at the same time. Stop command is defined by SW2.
SW1
FWD
SW2
K
EN
DZ B
Series
REV
COM
Fig. 6-8 Two-wire operation mode 1
1: Two-wire control, sepa rate Enable from direction. When this mode is used, the defined FWD is enable
terminal. The direction is determined by the de fined REV state.
K1
FWD
DZ B
K2
Series
RE V
DCM
K1
OFF
ON
OFF
ON
K2
OFF
Operation
Command
STOP
OFF
FWD
ON
STOP
ON
REV
Fig. 6-9 Two-wire operation mode 2
2: Three-wire control 1, integrate Enable with direction. At this mode, EN is the Enable terminal with the
direction controlled by the defi ned FWD. REV define the direction.
SW1
FWD
SW2
K
EN
DZ B
Series
RE V
K
OFF
Operation
Command
FWD
ON
REV
DCM
Fig. 6-11 Three-wire operation mode 2
S W 1:F WD o p er a ti ng b u tt on S W 2:S TO P b u tt on K:R EV o p er a ti n g b ut t on
EN is defining the corresponding terminal function as Function 3 “Three-wire operation control”.
Note: For two-wire operation mode, when FWD/REV terminal is enabled and the stop command
produced by other sources stops the equipment, the inverter does not st art to operate after the stop
command disappears even if the control terminal FWD/REV is still valid. If the inver ter needs to
operate, it is required to trigger FWD/REV again.
Function
Code
F2.08
Name
UP/DOWN frequency
increment variable rate
Setting Range
0 . 0 1~5 0 . 00 H z / s
Default
Value
0.50Hz/s
Terminal UP/DOWN regulates the change rate of frequency setting.
Function
Code
F2.09
Name
VI lower limit
F2.10
VI lower limit
corresponding setting
F2.11
F2.12
F2.13
VI upper limit
VI upper limit
corresponding setting
VI input filtering time
Setting Range
0 . 0 0V~1 0 .0 0 V
- 1 0 0 .0 %~1 0 0 .0 %
0 . 0 0V~1 0 .0 0 V
- 1 0 0 .0 %~1 0 0 .0 %
0 . 0 0s~1 0 .0 0 s
Default
Value
0.00V
0.0%
10.00V
100.0%
0.10s
Fig. 6-10 Three-wire opera tion mode 1
K:F W D/ RE V s wi t ch S W 1:R UN b ut t on SW 2:S T OP b u t to n
EN is defining the corresponding terminal function as Function 3 “Three-wire operation control”.
-49-
-50-