Chapter 5 Function Parameters List
Chapter 5 Function Parameters List
5/14/2018
Function
Code
Name
Setting Range
Input terminal status
4
Output terminal status
8
Default
Value
Fuling Inve r te r Use r Ma nua l - slide pdf.c om
Modifi Serial
cation No
Function
Code
Name
Setting Range
18:Communication fault(E018)
19:Current detect error(E015)
Default Modifi Serial
Value cation No
PID setpoint
16
PID feedback
32
VI value
64
CI value
128
Current segment of
multi-speed control
256
F3.07
operation status display
preferential option
0-14 (0:invalid)
0
F3.08 IGBT module temperature 0100.0
F3.09 Software version
F3.10
Accumulative operating
time
06 55 35 h
0
F3.11
The fault before previous
fault type
F3.12 Previous fault type
0No fault
1:IGBT U phase protection(E009)
2:IGBT V phase protection(E019)
F3.13 Current fault type
3:IGBT W phase protection(E029)
4:Acceleration over-current(E004)
5:Deceleration over-current(E005)
6:Constant speed over-current
(E006)
7:Acceleration over-voltage(E002)
8:Deceleration over-voltage(E00A)
9:Constant speed over-voltage
(E003)
10:Bus under-voltage faultE001
11:Motor overload(E007)
12:Invertero verload(E008)
13:Input side phase failure(E012)
14:Output side phase failure(E013)
15:(Diode module overheat fault
(E00E)
16:IGBT module overheat fault
(E01E)
17:External fault(E017)
85.
** 86.
** 87.
** 88.
** 89.
** 90.
** 91.
F3.14
Operating frequency at
current fault
20:Motor self-learning error(E016)
21:EEPROM operation error
(E00F)
22:PID feedback disconnect error
(E02E)
23:Braking uniterrorE01A
24:Reserved
0.00Hz
F3.15
F3.16
F3.17
F3.18
F4.00
Ocuurtrpeunttafamuplterage at
Bus voltage at current fault
Input terminal status at
current fault
Output terminal status at
current fault
F4 Application Function Parameters
ACCEL Time 2
0 .13 6 00 . 0 s
0.0A
0.0V
0
0
10.0s
F4.01
F4.02
F4.03
F4.04
F4.05
F4.06
F4.07
DECELTime 2
Jogging frequency
0 .13 6 00 . 0 s
0 .0 0F 0 .0 4
JoggingACCEL time
0 .13 6 00 . 0 s
Jogging DECEL time
0 .13 6 00 . 0 s
Skip frequency
0 .0 0F 0 .0 4
Skip frequency range
0 .0 0F 0 .0 4
Traverse frequency range
0 .01 0 0. 0%
relative to set frequency
F4.08 Kick frequency range
0.050.0%(relativeto traverse
frequency range)
F4.09
F4.10
F4.11
F4.12
Traverse frequency up
time
0 .13 6 00 . 0 s
Traverse frequency down
time
0 .13 6 00 . 0 s
Fault auto-reset times
03
Interval time setting of
automatic resetting fault
0 . 11 00 . 0s
10.0s
5.00Hz
10.0s
10.0s
0.00Hz
0.00Hz
0.0%
0.0%
5.0s
5.0s
0
1.0s
** 92.
** 93.
** 94.
** 95.
** 96.
97.
98.
99.
100.
101.
102.
103.
104.
105.
106.
107.
108.
109.
-29-
-30-