DZB Series
Chapter 5 Function Parameters List
DZB Series
Chapter 5 Function Parameters List
5/14/2018
Fuling Inve r te r Use r Ma nua l - slide pdf.c om
Function
Code
Name
Setting Range
F0 Basic Function Parameters
F0. 00 Cont r ol mode
0Speed sensorless vector
control (SVC)
1V/ F c ontr ol
F0.01
Command source
selection
0K e yb o ar d
1Ter minal
2Communi c ati on
F0.02
Keyboard and terminal
UP/DOWN setting
0Valid, and inverter memorize
when power down
1Valid, and inverter does not
memorize when power down
Default Modifi Serial
Value cation No
1
0.
0
1.
0
2.
2I nv al id
0K e yb o ar d
1 VI
F0.03
Frequency command
Selection
2 CI
3V I+ C I
4: Multi-speed
5: PID control
6: Communication
F0.04 Maximum output frequency 10. 00600.00Hz
F0.05 Upper limit frequency
F0.06F0. 04
F0.06 Lower limit frequency
0. 00 HzF0. 05
F0.07 Keyboard frequency setting 0. 00 HzF0. 04
F0.08 ACCEL time 1
0.13600. 0s
F0.09 DECEL time 1
0. 13600. 0s
0Operating at default direction
F0.10 Osepleercatitoionn direction
1Operating at reverse direction
2NO inverse operating
F0.11 Carrier frequency setting
F0.12
Functional parameters
restoration
1. 015. 0k Hz
0NO operat ion
1Restore default value
2Delete failure records
F0.13 AVR selection
0I nv a li d
1Valid all the time
0
50.00Hz
50.00Hz
0.00Hz
50.00Hz
10.0s
10.0s
2
Set by
model
0
1
3.
4.
5.
6.
7.
8.
9.
10 .
11.
12 .
13 .
Function
Code
Name
Setting Range
2Invalid during deceleration
0Di rec t s t art
Default Modifi Serial
Value cation No
F0.14
F0.15
F0.16
F0.17
F0.18
F0.19
F0.20
F0.21
F0.22
F0.23
F0.24
F0.25
F1.00
F1.01
F1.02
F1.03
F1.04
F1.05
F1.06
F1.07
F1.08
Start Mode
1DC braking first and then start
0
2Running speed pick-up and
then start
Start frequency
0. 0010. 00Hz
0.50Hz
Hold time of start
frequency
0 .05 0 .0 s
0.0s
Braking current
before starting
0 .01 5 0. 0 %
0.0%
Braking time
before starting
0 .05 0 .0 s
0.0s
0DECEL St op
Stop Mode
0
1Fr ee run St op
Beginning Frequency of
braking
0 .0 0F 0. 04
0.00Hz
Waiting time of braking
0 .05 0 .0 s
0.0s
DC braking current
0 .01 5 0. 0 %
0.0%
DC braking time
0 .05 0 .0 s
0.0s
Dead time between
forward and reverse
Terminal command
protection when
power on
0. 03600. 0s
0Terminal command invalid
when power on
1Terminal command valid when
power on
0.0s
01
F1 Motor Parameters
Inverter model
Motor rated power
Motor rated frequency
Motor rated speed
Motor rated voltage
Motor rated current
Motor stator resistance
Motor rotor resistance
Motor stator/rotor
inductance
0B m ode l
1P m o de l
0. 4900.0k W
0. 01HzF0. 04
0 3 6 0 00 rp m
046 0V
0. 11000. 0A
0. 00165.535Ω
0. 00165.535Ω
0. 16553. 5mH
Set by
model
Set by
model
50.00Hz
Set by
model
Set by
model
Set by
model
Set by
model
Set by
model
Set by
model
14 .
15 .
16 .
17 .
18 .
19 .
20 .
21 .
22 .
23 .
24 .
25 .
26 .
27 .
28 .
29 .
30 .
31 .
32 .
33 .
34 .
-23-
-24-
http://slide pdf.c om/re a de r/full/fuling-inve r te r-use r-ma nua l