DZB100 Series
Installation and Wiring
2.2 Wiring
Main Circuit Wiring
(1) Power terminal block designations
Power input and output may be connected via a nine or ten position termina block. The pin
assignments are as follows:
Model
Applicable motor
capacity
Power terminal pin assignments
FL08
FL22
0.55~0.75KW(220V Series)
1.5KW (220V Series)
0.75~2.2KW(380V Series)
RS T
Earth AC Input Line
Ground Terminals
U V W BR+ BR-
Motor
Connection
Breaking
Resistor
FL28
0.75~1.5KW (220V Series)
0.75~1.5KW(380V Series)
R S T BR+ BR- U V W
Earth AC Input Line
Ground Terminals
Breaking
Resistor
Motor
Connection
FL37
2.2~3.7KW(220VGrade)
2.2~5.5KW (380V Series)
E R S T BR+ BR- U V W
Earth AC Input Line
Ground Terminals
Breaking
Resistor
Motor
Connection
FL75
FL015
7.5~15KW(380V Series)
E R S T BR+ BR- U V W
Earth AC Input Line Breaking
Ground Terminals
Resistor
Motor
Connection
FL030
18.5~30KW(380V Series)
FL045
FL075
FL132
37~45KW (380V Series)
55~75KW(380V Series)
93~132KW(380V Series)
FL160
132~160KW(380V Series)
FL220
187~280KW(380V Series)
R S T P1 P2 DC- U V W
AC Input Line
Terminals
Breaking
Unit
Motor
Connection
Earth
Ground
R S T DC+ DC- U V W E
AC Input Line
Terminals
Breaking
Unit
Motor
Earth
Connection Ground
R S T U VW
AC Input Line
Terminals
Motor
Earth
Connection Ground
-6-
    "