DZB100 Series
Appendix
Appendix A: Standard Specifications
Item
Description
Rated Voltage
Frequency
Maximum Output
Voltage
Output Frequency
Overload Endurance
220V Class:220V 20 50/60Hz 5Hz
380V Class:380V 20 50/60Hz 5Hz
Proportional to Input Voltage
0.01Hz-400.00Hz (The frequency can be reached to 1500Hz by 100HSeries AC Motor Drives.)
150% of rated current for 1 minute
Control system
V / F pattern
Frequency setting
precision
Frequency resolving
capability
Slip compensation
Torque compensation
Accel/decel time
Multi-step operation
Internal Counter
SPWM (Sinusoidal Pulse Width Modulation, carrier frequency 1-15kHz)
V/F pattern,Adjustable V/F pattern
0.01Hz
Digital setting:0.01Hz Analog setting:Maximum frequency 0.1
Aoto slip compensation,range:0.00-10.00
Manual/aoto torque compensation,range:0%-10%
Two curve:linear and s-curve;
Two accel/decel curve,range:1.0-999.9
Internal PLC operation;Multi-function terminal input
Realize product-line automatic count control
Operation
Setting Signal
Digital operation(Setting by RUN, STOP, FWD / REV);
External signa(FWD, REV, EF can be combined for 2 or 3-wire operation,
RS-485 serial interface.)
Frequency setting
Digital operation(Setting by up/down or JOG key);
External signal(Multi-function 1~4,JOG, Multi-step speed, Up / Down,
0 to 10 VDC, 4~20mA,RS-485 serial port)
Input signal
Multi-step selection 1 ~7, Jogging, Accel. / Decel. Prohibit, First / Second
Accel. / Decel. Switching command, External BB (NC, NO selection), etc.
Output signal
During running, Up to frequency setting, Up to desired frequency setting
Count out detection, Non zero-speed, Over-torque detection, etc.
Analog / Digital Output Analog frequency / current signal output, digital frequency signal output
Other function
Automatic Voltage Regulation (AVR), S-Curve, over voltage,
over-current stall prevention,abnormal records checking,Frequency limit,
Carrier-frequency adjustable, DC braking, DB starting frequency setting,
Momentary power failure restart, over-voltage stall prevention, etc.
Display
Displays:pre-set frequency;operate frequency;output current;moto speed;
internal count value;fault information,etc
Protective function
Installation site
Altitude
Ambient temperature
Ambient Humidity
Vibration
Storage temperature
Frame Defend grade
Cooling Method
Over-current, over voltage, under voltage, overheat ground fault,overload
limit, over voltage supply, short-circuit protection of output terminals,etc.
Indoor(no straight sunshine,keep from corrosive gasses, liquid and dust
1,000m or lower
-10 ~+40
Below 90% RH (non-condensing)
1.0G less than 20Hz, 0.6G at 20~50Hz
-20 -60
IP20
Forced air-cooling