DZB100 Series
Parameter Settings
F1-63 F1-66 Count Down Value Attained Setting
F1-
63
Parameter Name Pre-set count down value attained
Factory Setting 5
Unit 1
Settings 1 9999
When the internal counter, triggered by the external input TRG, counts down and reaches
this specified value, the specified output terminal (MO1) will be closed (assuming that
F1-45 is set to 0003). The output terminal (MO1) will be opened when the internal counter
reaches the value specified in F1-66. (See chart below)
F1-
66
Parameter Name Count Down Value Setting
Factory Setting 10
Unit 1
Settings 1 9999
This parameter determines the value of the internal counter. The internal counter may be
triggered by an external signal via the external input TRG terminal.
Upon completion of the countdown, the specified output terminal (MO2) will be closed
(assuming that F1-46 is set to 0003). (See chart below)
The timing chart is illustrated as follows:
F1-45 =0003
F1-46 =0003
F1-63 =0005
F1-66 =0010
Application example:
Control
c10 c09 c08 c07 c06 c05 c04 c03 c02 c01
terminaL TRG
T2
Control
T1
terminaL M01
""
Control
""
terminaL M02
Note: The minimum On time for T2 is 2 msec or more.
The minimum cycle time for T1 is 6 msec. or more.
c10 c09 c08
-56-
    "