DZB100 Series
Parameter Settings
F1-64 Function Display Setting
F1-
64
Parameter Name Displays the contents of the monitored item
Factory Setting 0000
Settings 0000 Displays the actual operating frequency(p)
0001 Displays the user-defined setting(n)
0002 Displays the value of the internal counter(r)
0003 Displays the input voltage(u)
0004~0012 Reserved
Displays the contents of the monitored item as follows:
p Displays the actual operation frequency
n Displays the user-defined setting ( where n=p F1-65
r Displays the value of the internal counter. This counter is triggered by an external
signal provided via the external input TRG. When the counter reaches 0000 during
count down, the multi-function output terminal MO1 or MO2 will be "closed"
(Refer to F1-45, 46). The counter will use the value contained in F1-66 as its starting
point when another count down is to be executed.
F1-65 Coefficient K Setting
F1-
65
Parameter Name Coefficient of line speed
Factory Setting 60
Unit 1
Settings 1 2000
This parameter can be programmed while the drive is running.
Coefficient K determines the multiplying factor for the user-defined setting (n).
The value of the user-defined setting (n) is calculated and displayed as follows:
Display value of n = output frequency K.
-55-