DZB100 Series
Parameter Settings
0008
0009
0010
0011
0012
0013
0014
0015
0016
0017
0018
0019
0020
0021
0022
When "Closed", the AC Drive output frequency is increased.
When "Closed", the AC Drive output frequency is decreased.
When "Closed", the internal counter is set to zero.
When "Closed", the jog reference frequency in the forward direction is selected.
When "Closed", the jog reference frequency in the reverse direction is selected.
When "Closed", the AC drive external fault.
When "Open", the AC drive external fault.
When "Closed", the AC drive output is turned off, no longer startup.
When "Open", the AC drive output is turned off, no longer startup.
When "Closed", all Parameters are locked.
When "Closed", the operating command comes from digital panel.
When "Closed", the master frequency command comes from digital panel.
Reserved
When "Closed", the AC Drive output frequency is increased slow-paced.
When "Closed", the AC Drive output frequency is decreased slow-paced.
F1-16 STEP1
F1-17 STEP2
F1-18 STEP3
F1-19 STEP4
F1-20 STEP5
F1-21 STEP6
F1-22 STEP7
Hz
Master frequency
reference
MI 1-DCM
MI 2-DCM
MI 3-DCM
STEP1
STEP2
STEP3
STEP5
STEP4
STEP6
STEP7
ON
ON
ON ON
ON
ON
ON ON
ON ON ON ON
Time
FWD RUN COMMAND
UP COMMAND
DOWN COMMAND
MAX. OUTPUT FREQUENCY
MIN. OUTPUT FREQUENCY
UP TO FREQUENCY SETTING SIGNAL
Note: When both the Up and Down command terminals are "closed", the AC drive neither
accelerates or decelerates. The output frequency is also held constant.
-46-