DZB100 Series
Parameter Settings
F1-36 F1-37 Reference Frequency Upper / Lower Limit
F1-
36
Parameter Name Reference frequency upper limit setting
Factory Setting 200.00Hz
Unit 0.01Hz
Settings 0.01 400.00Hz
Determines the upper limit of the reference frequency in 0.01 Hz increments.
F1-
37
Parameter Name Reference frequency lower limit setting
Factory Setting 0.00Hz
Unit 0.01Hz
Settings 0.00 400.00Hz
Determines the lower limit of the reference frequency in 0.01 Hz increments.
Output frequency
F1-03
F1-36
F1-37
F1-03
Input frequency
-43-
    "