DZB100 Series
Parameter Settings
F1-15 S-curve
F1-
15
Parameter Name S-curve setting
Factory Setting 0
Settings 0 7
This parameter should be set during start-up. It is used to provide smooth acceleration and
deceleration. The S-curve may be set from 1 to 7.
Frequency
F1-15 0001
"S curve enabled"
S-curve characteristics Time
Accel Time
1 or 2
Time
F1-15=0001
"S curve disabled"
Time
Decel Time
1 or 2
F1-16 F1-17 F1-18 F1-19 F1-20 F1-21 F1-22 Multi-speed Operation
F1-
16 17 18 19 20 21 22
Parameter Name Multi-step speed setting 1, 2, 3, 4, 5, 6, 7
Factory Setting 0.00Hz
Unit 0.01Hz
Settings 0.00 400.00Hz
These parameters can be programmed while the drive is running.
The multi-function input terminals (refer to parameters 39, 40, 41,and 42) are used to select
one of eight AC drive Multi-Speed output frequencies. The frequency is determined by
F1-16 to 22.
-35-