DZB100 Series
Parameter Settings
F1-10 F1-11 F1-12 F1-13 Accel / Decel Time Setting
F1-
10
Parameter Name Acceleration time 1
Factory Setting 10.0sec
Unit 0.1sec
Settings 0.1 999.9sec
This parameter can be programmed while the drive is running.
This parameter is used to determine the time required for the AC drive to ramp from 0 Hz to
its Maximum operating frequency(F1-03) . The rate is linear unless S Curve is "Enabled".
F1-
11
Parameter Name Deceleration time 1
Factory Setting 10.0sec
Unit 0.1sec
Settings 0.1 999.9sec
This parameter can be programmed while the drive is running.
This parameter is used to determine the time required for the AC drive to decelerate from the
Maximum operating frequency (F1-03) down to 0 Hz. The rate is linear unless S Curve is
"Enabled".
Speed
Command frequency
Accel time
F1-10 or F1-12
Time
Decel time
F1-11 or F1-13
-33-
    "