DZB100 Series
Digital Keypad Operation
Key
PRGM
RESET
FUNC
DATA
FWD
REV
JOG
RUN
STOP
Description
Program / Reset
Used to select the Normal mode of operation or to program the AC drive when
either the drive is running or has stopped. Switch to the PRGM mode to select
a parameter or change the setting of a parameter. If the AC drive has stopped
due to a fault, press this button to reset the drive.
Function / Data
Displays information on the AC drive status such as the reference frequency,
output frequency, or output current in the normal mode. While the drive is in
the Program Mode, press this key once to display the current parameters.
After changing the parameters, press this key again to store the new parameters.
Forward / Reverse
Used to toggle between forward and reverse operation.
Pressing this key will cause the motor to ramp down to 0 Hz and then ramp up
to the preset speed in the opposite direction. By default, the digital keypad
controls the AC drive forward/reverse operation.
To control the forward/reverse operation via the control terminal block,
change the F1-01 parameter to 0001 or 0002 .
Jog
Used to start the AC drive, then run at the jog frequency as set by the parameter
specified under F1-23 [Jog Frequency].
Run
Used to start the AC drive operation.
This key has no effect when the drive is set to terminal run.
Stop
Used to stop the AC drive operation.
Up / Down
Press the "Up" or "Down" button to change parameter settings.
These keys may also be used to scroll through different operating values or
parameters.
Note: Pressing the "Up" or "Down" button momentarily changes the parameter settings in
increments. Press and hold down either of these keys to rapidly run through the possible
settings.
-14-