Laser Engraving & Cutting Control System Manual
4.5.2 Laser Set
Select LASER SET by cursor and press ENTER:
The default value of time is 0 ms, default power value is100%;
Press < > to move the cursor to choose Time or Power;
Press ∧ ∨to set parameters, setting=1
Time ranged from 0 to 99999ms. Power ranged from 0 to 100%. Press ENTER to make the
settings effective.
Press ESC to return to supporting interface while the settings won’t be effective.
If the time=0, laser will be on immediately upon pressing the button LASER, and be off
when stop pressing. If time is set to be a fixed value, laser will be on a certain time for each press.
4.5.3 Jog Set
Select JOG SET by cursor and press ENTER:
Press ∧ ∨ to set parameters. Press ENTER to confirm and return to supporting interface.
The default value =0, start moving upon pressing < > ∧ ∨, and stop when stop pressing. If
the value is not 0, laser head start moving a fixed distance at high speed.
4.5.4 IP Set
Press < > to move the cursor and press ∧ ∨to set parameters, setting=1
Machine ID: When one LaserCut controls several machines, the machine ID should be set on
the PAD panel. It is suggested that the ID should not be the same.
49
    "