Laser Engraving & Cutting Control System Manual
Delay after laser on: set the delay after the laser is on.
Delay before laser off: set the delay before the laser is off.
Delay after laser off: set the delay after the laser is off.
3.5.3 Set Engrave Parameters
Engrave Speed: engraving speed on X-axis.
Power1/2: adjust the laser power (unit: %).
Step Distance: movement distance on Y-axis when engrave a row on X-axis.
Bi-direction: laser is on both on positive and negative X-axis when this parameter is chose.
The efficiency is high, but if you need a high process precision, do not choose this option. The
efficiency will be cut half.
Engrave Blow: blow or not, with this option selected or not.
Direction: this is the engrave direction.
Filled by Circles:
Select the option and graph will be filled by circles with the radius you set.
Male Engrave: define the engrave way of the circles.
Circle Radius: radius of the circle.
Circle Gap: space between the circles.
Light Guide Plate: choose this option and the system will convert the data to dot matrix data
for light guide plate.