Laser Engraving & Cutting Control System Manual
Sample of “Divide Height” (There are 6 sections (20mm*20m), and each includes 8
triangles).
Divide height value 25 means the whole graph is divided into 6 sections (25mm*25mm). The
6 area run sequence 1→ 2→ 3→ 4→ 5→ 6.
Start Pos:
This is the start position of the cutting route. There are 4 options: Left Bottom, Right Bottom,
Left Up, and Right Up.
Auto Set Start Point:
Check this option and the system will adjust the start point to get shortest path.
Backlash Optimize:
Check this option and the system will automatically define cut direction to compensate the
backlash in cutting. But it will increase the idle movement. Generally, this option won’t be
checked.
22
    "